              Ophthalmic sodium hyaluronate 1.Introduction 1).Can prevent the tissue being damaged from surgical instrument through shock absorption and cell layer lubrication; 2).High viscoelastisity can maintain good surgery space'; 3).High purity and high transparencr can mainain the goo......

              Send Inquiry

              Product Description

              Ophthalmic sodium hyaluronate
               
              1.Introduction 
               

                    1).Can prevent the tissue being damaged from surgical instrument through shock absorption and cell layer lubrication;
               
                    2).High viscoelastisity can maintain good surgery space';
               
                    3).High purity and high transparencr can mainain the good view for surgery operation'
               
                    4). No need for cold storage.
               
              Best Viscoelastic Solution for Corneal Transplant Surgery in Endothelium Protection



              2.Application:

               
                    1).Cataract extraction surgery
               
                    2).Cataract ultrasonic phacoemulsifiation
               
                    3).Corneal transplant surgery
               
                    4).Glaucoma surgery
               
                    5).Retinal detachment 
               
                    6).Intraocular lens implantation 
               
                    7).Removal, iridectomy, trabeculectomy, ocular trama surgery 
               
                    8).Ophthelmic surgery and other surgery
               
              Best Viscoelastic Solution for Corneal Transplant Surgery in Endothelium Protection

               
              3.specification

               
              Modle No.VolumeConcentrationPacking
              SC-15-1.01.0ml15mg/mlprefilled
              syringe
              in blister

              Usage and dosage:

                    A Cataract extraction surgery,IOL implantation:0.20~0.75ml into anterior chamber,0.1ml on the  IOL spreading.
                    B Cataract surgery: 0.1~0.5ml injection into anterior chamber.
                    C IOL implantation:before implantation 0.1~0.5ml injection into anterior chamber,0.1ml on the  IOL spreading.
                    D Corneal transplant surgery:after removal of corneal,0.1~0.5ml injection into anterior chamber,after transplant of corneal spreading around 0.1ml.
               
              4.Characteristic
               
                    1). Highest Concentration (20mg/ml) domestic viscoelastic solution
                    2). Viscoelastic solution,no need for cold storage
                    3). Super high molecule weight 2.2 Mil.-4 Mil.Dalton,exceed the  professional standard (0.8Mil.Dalton) 3-5 times,is,the,guarantee basis of pseudoplasticity,viscocity,elasticity, cohesiveness and paintability.
               
              5.Product advantages:

                    1). Non-animal source     
                    2). Good biocompatibility    
                    3). High viscoelasticity    
                    4). High lubricity      
                    5). High physical alterability

              6.Scope of application:

              Used as ophthalmic viscoelastic device.
                    1).Cataract extraction surgery                                                              
                    2).Cataract ultrasonic phacoemulsifiation
                    3).Corneal transplant surgery                                                              
                    4).Glaucoma surgery
                    5).Retinal detachment                                                                           
                    6).Intraocular lens implantation 
                    7).Removal, iridectomy, trabeculectomy, ocular trama surgery       
                    8).Ophthelmic surgery and other surgery
               
              7.Business Scope

              Our business scope including:
                    Singclean™  Medical Sodium Hyaluronate Gel for Anti-adhesion Gel
                    Quickclean™ Hyaluronic acid gel for intra-articular injection
                    Singclean™  Hyaluronic acid gel for Ophtahlmic Surgery
                    Singfiller ® Cross-linked dermal filler for plastical dermal filler
                    Quickclean™ Bacterial  vaginosis diagnostic  strip sets
                    Quickclean™ Absorbable  Hemostatic powder and gauze
                    Quickclean™ Absorbable  Hemostatic Gauze of Oxidized Regenerated Cellulose

               
              8.Company profiles
                    Hangzhou Singclean Medical Products Co., Ltd., established in March 2003 with registered capital of 80,000,000 RMB, is a national high and new technology enterprise integrating the R&D, production and sales of medical biomaterials. With well-qualified staff, thorough quality management system and first-class facilities, the company ensures the continuous production of medical devices and drug injection products of Class III that confirm to the laws and regulations of the State Food and Drug Administration (SFDA) and EU MDD.
                    The plant has introduced successively production facilities such as import sterilization filtration system, import PLÜMAT filling machines, LD500-4 horizontal tube multi-effect water distiller, DPB-250G plate automatic blister packaging machine, import Super-Q ultra-pure water equipment, 1T / h RO and DI water purification systems

              Best Viscoelastic Solution for Corneal Transplant Surgery in Endothelium Protection

               
              9.Certification
               
                    CE, SGS, ISO13485, ISO9001
              Best Viscoelastic Solution for Corneal Transplant Surgery in Endothelium Protection


              10.Storage: 
                    Store at 2-30°C. Do not freeze.
                    Protect from light source.
                    Do not use after the Expiration date. 
                    Store for two years.

              11.Our Services
                    > 24 hours online services
                    > OEM,ODM and Customized is available
                    > Quckly delivery time
                    > Quickly and professional after sales service
               

              Related Category

              Send Inquiry

              Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
              Click Refresh verification code

              Leave Your Message

              • Click Refresh verification code