Home > Products > Disposable Medical Supplies > Home Use Easy High Accuracy 99% Sensitivity Diagnostic Kit Fecal Occult Blood Fob Test Kit with Ce
              Home Use Easy High Accuracy 99% Sensitivity Diagnostic Kit Fecal Occult Blood Fob Test Kit with Ce
              • Home Use Easy High Accuracy 99% Sensitivity Diagnostic Kit Fecal Occult Blood Fob Test Kit with CeHome Use Easy High Accuracy 99% Sensitivity Diagnostic Kit Fecal Occult Blood Fob Test Kit with Ce
              • Home Use Easy High Accuracy 99% Sensitivity Diagnostic Kit Fecal Occult Blood Fob Test Kit with CeHome Use Easy High Accuracy 99% Sensitivity Diagnostic Kit Fecal Occult Blood Fob Test Kit with Ce
              • Home Use Easy High Accuracy 99% Sensitivity Diagnostic Kit Fecal Occult Blood Fob Test Kit with CeHome Use Easy High Accuracy 99% Sensitivity Diagnostic Kit Fecal Occult Blood Fob Test Kit with Ce
              • Home Use Easy High Accuracy 99% Sensitivity Diagnostic Kit Fecal Occult Blood Fob Test Kit with CeHome Use Easy High Accuracy 99% Sensitivity Diagnostic Kit Fecal Occult Blood Fob Test Kit with Ce

              Home Use Easy High Accuracy 99% Sensitivity Diagnostic Kit Fecal Occult Blood Fob Test Kit with Ce

              Home Use Easy High Accuracy 99% Sensitivity Diagnostic Kit Fecal Occult Blood FOB Test kit With CEProduct Description♣Introduction:The presence of fecal occult blood in the stool is associated with gastrointestinal disorders such as polyps, diverticulitis&......

              Send Inquiry

              Product Description

                        Home Use Easy High Accuracy 99% Sensitivity Diagnostic Kit Fecal Occult Blood FOB Test kit With CE

              Product Description
              ♣Introduction:
              The presence of fecal occult blood in the stool is associated with gastrointestinal disorders such as polyps, diverticulitis, and Crohn's disease, which may lead to colorectal cancer if not detected and treated early. Compared to the widely available Guaiac test, the One Step Fecal Occult Blood Test by Blue Cross is an immunochemical assay with much higher sensitivity and is designed to be more specific in detecting low levels of human fecal occult blood. It does not require special dietary restriction on patients. One Step Fecal Occult Blood Test is a rapid test that can be performed without the use of an instrument. Test yields a positive result when the concentration of hHb in test specimen is at or above 100ng/ml.
              ♣ Storage&Stability:
              The test kit can be stored at temperatures from 4°C to 30°c in the sealed pouch up to date ofexpiration.The test kit should be kept away from direct sunlight and moisture.Do not freeze the test kit.
              ♣ Specimen Collection:
              Blood should be collected aseptically into a clean tube without anticoagulants.Separate the serum or plasma from blood as soon as possible to avoid hemolysis.Use clear non-hemolyzed specimens when possible.
              FormatSpecimenSize(mm)
              StripWhole Blood/Serum2.5,3.0
              CassetteWhole Blood/Serum3.0,4.0
              StripSerum/Plasma2.5,3.0
              CassetteSerum/Plasma2.0,4.0
              Test Procedure:
              1. Allow the test kit,specimen,and/or controls to equilibrate to room temperature(15-30°C) prior to testing.
              2. Remove the test kit from the foil pouch and use it as soon as possible.Best results will be obtained if the assay is performed within one hour.  
              3. Place the test device on a clean and level surface.Transfer the specimen by a disposable specimen dropper(or a pipette):To use a hold the dropper vertically,draw the specimen up to the fill line as shown in illustration below(approximately 40uL). Transfer the specimen to the specimen well(S) of the test device and start the timer.Aviod trapping air bubbles in the specimen well (S).
              4. Wait for the red line(s) to appear.The result should be read at 15 minutes.Do not interpret the results after 20 minutes.

               
              Product details
               
              Results:
              Positive:
              In addition to a pink colored control (C) band,a Distinct pink colored band will also appear in the test (T) region. 
              *Note (Weak Positive): Colored band appearing in control Region (C) together with a faint colored band in Test Region (T).
              Negative:
              Only one colored band appears on the control (C) region.No apparent band on the test (T) region.
              Invalid:
              A total absence of color in both regions is an indication of procedure error and/or the test reagent has deteriorated.

               

              Our service
              1.Our serveces
              GEMC is the short name of Gem Medic Electric & Technology Co.,Ltd located in Henan Province, China, which is a privately-held corporation high-tech enterprise specializing in trade of rapid medic diagnostic test kits and device. The main products we supply are pregnancy test kits, ovulation test kits, sperm fertility test, drug of abuse test, infectious disease test, saliva alcohol tester, digital clinical thermometer, blood pressure monitor,ovulation microscope monitor and other medical test device.
              Since the foundation of company, based on the belief-product quality and service are the lifeline of enterprise, so now we have had global customers from all of over the world, such as France, Russia, UAE, Brazil, Mexico, Peru and south Africa, totally more than 70 countries and areas.
              And we will sincerly hope supply more & better service for you, 'for your better health & happy life' is our working target, welcome to visit our website to know more about it, thanks.

              2. How to order our product
              (1) Customers to contact to consult , and purchase our products
              (2) Our trader make a perfessional form according to your product
              (3) Inform the product you need after you confirmation of the product



              FAQ
              Q1: What's the method u use to do the test?
              A: Colloidal Gold Method.


              Q2: What's ur MOQ ?
              A: Always, for strip format, the MOQ is 5000pcs. While for cassette format, MOQ is 2000pcs, same as midstream.


              Q3: What's ur packing of the tests?
              A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.


              Q4: What's the main differences when comparing products from different suppliers?
              A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.
               
              Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
              A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.


              Q6: How can i distinguish a good test kit?
              A: U can judge from the 4facts:Technical data: Such as the accuracy, specificity and sensitivity.
              Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.

              Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.

              Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice



              Contact us
              Telephone: 86-371-60997506 
              Fax: 86-371-60997506
              Website: http://gv-medic.en.made-in-china.com
              Address: NO.20,Bosong Road, Zhengzhou, Henan ,China
              Zip: 450001
              City: Zhengzhou
              Country: China (Mainland)
               

              Related Category

              Send Inquiry

              Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
              Click Refresh verification code

              Leave Your Message

              • Click Refresh verification code